Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Respir Crit Care Med ; 205(5): 529-539, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34784492

RESUMO

Rationale: The cystic fibrosis (CF) modulator drug, elexacaftor/tezacaftor/ivacaftor (ETI), proved highly effective in controlled clinical trials for individuals with at least one F508del allele, which occurs in at least 85% of people with CF. Objectives: PROMISE is a postapproval study to understand the broad effects of ETI through 30 months' clinical use in a more diverse U.S. patient population with planned analyses after 6 months. Methods: Prospective, observational study in 487 people with CF age 12 years or older with at least one F508del allele starting ETI for the first time. Assessments occurred before and 1, 3, and 6 months into ETI therapy. Outcomes included change in percent predicted FEV1 (ppFEV1), sweat chloride concentration, body mass index (BMI), and self-reported respiratory symptoms. Measurements and Main Results: Average age was 25.1 years, and 44.1% entered the study using tezacaftor/ivacaftor or lumacaftor/ivacaftor, whereas 6.7% were using ivacaftor, consistent with F508del homozygosity and G551D allele, respectively. At 6 months into ETI therapy, ppFEV1 improved 9.76 percentage points (95% confidence interval [CI], 8.76 to 10.76) from baseline, cystic fibrosis questionnaire-revised respiratory domain score improved 20.4 points (95% CI, 18.3 to 22.5), and sweat chloride decreased -41.7 mmol/L (95% CI, -43.8 to -39.6). BMI also significantly increased. Changes were larger in those naive to modulators but substantial in all groups, including those treated with ivacaftor at baseline. Conclusions: ETI by clinical prescription provided large improvements in lung function, respiratory symptoms, and BMI in a diverse population naive to modulator drug therapy, using existing two-drug combinations, or using ivacaftor alone. Each group also experienced significant reductions in sweat chloride concentration, which correlated with improved ppFEV1 in the overall study population. Clinical trial registered with www.clinicaltrials.gov (NCT NCT04038047).


Assuntos
Fibrose Cística , Adulto , Aminofenóis/uso terapêutico , Benzodioxóis/uso terapêutico , Criança , Agonistas dos Canais de Cloreto/uso terapêutico , Cloretos/análise , Fibrose Cística/tratamento farmacológico , Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística , Combinação de Medicamentos , Humanos , Indóis , Mutação , Estudos Prospectivos , Pirazóis , Piridinas , Pirrolidinas , Quinolonas , Resultado do Tratamento
2.
Am J Respir Crit Care Med ; 182(11): 1387-97, 2010 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-20622043

RESUMO

RATIONALE: The conducting of clinical trials in infants with cystic fibrosis (CF) has been hindered by lack of sensitive outcome measures. OBJECTIVES: To evaluate safety, feasibility, and ability to detect abnormalities in lung function of serial pulmonary function tests (PFTs) in infants with CF. METHODS: Multicenter observational study using a commercial device, rigorous training, ongoing quality control, and over-reading of data by an independent panel. Raised volume rapid thoracoabdominal compression technique and plethysmography were performed at enrollment and at 6 and 12 months, with an additional 1-month reproducibility visit. MEASUREMENTS AND MAIN RESULTS: A total of 342 procedures were performed in 100 infants with CF at 10 centers. FRC measurements were acceptable at a higher proportion of study visits (89%) than raised volume (72%) or fractional lung volume (68%) measurements. Average Z scores for many parameters differed significantly from historical control values. Mean (95% confidence interval) Z scores were: -0.52 (-0.78 to -0.25) for forced expiratory flow at 75% (FEF75) for FVC; 1.92 (1.39-2.45) for FRC; 1.22 (0.68-1.76) for residual volume; 0.87 (0.60-1.13) for FRC/total lung capacity; and 0.66 (0.27-1.06) for residual volume/total lung capacity. For future multicenter clinical trials using infant PFTs as primary endpoints, minimum detectable treatment effects are presented for several sample sizes. CONCLUSIONS: In this 10-center study, key PFT measures were significantly different in infants with CF than in historical control subjects. However, infant PFTs do not yet appear ready as primary efficacy endpoints for multicenter clinical trials, particularly at inexperienced sites, based on acceptability rates, variability, and potentially large sample sizes required to detect reasonable treatment effects.


Assuntos
Ensaios Clínicos como Assunto , Fibrose Cística/diagnóstico , Estudos de Viabilidade , Feminino , Volume Expiratório Forçado , Humanos , Lactente , Estudos Longitudinais , Masculino , Pletismografia/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Testes de Função Respiratória/métodos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...